Operating Slaughterhouse Wastewater Project / Hunan

100 m3/day Slaughterhouse Wastewater Treatment Project In Hunan

For this pig-farm slaughterhouse project, we combined solid-liquid separation, Anaerobic-Oxic (A/O) biological treatment and coagulant-assisted sedimentation in an integrated system designed for approximately 100 m3/day.

100 m3/day

Approximate treatment capacity

Hunan, China

Project location

A/O + Settling

Main treatment route

Operating

Installed and commissioned
Project Overview

What Motiva Configured For The Project

The route was built around coarse-solids removal, staged biological treatment and final clarification for a high-strength slaughterhouse wastewater source.

Project At A Glance

LocationHunan, China
Wastewater SourcePig-farm slaughterhouse wastewater
Stated CapacityApproximately 100 m3/day
Main Pollutant ConcernsHigh organic load, suspended solids and ammonia nitrogen
Main ProcessSolid-liquid separation + Anaerobic-Oxic (A/O) biological treatment + sedimentation
Final ClarificationCoagulant addition followed by gravity settling
Project ServicesDesign, installation, commissioning and after-sales support
Project StageInstalled, commissioned and operating
Design A Comparable System

Confirm The Load, Peaks And Outlet Before Sizing

A new slaughterhouse project should begin with actual production and wastewater data. The daily average alone does not define pretreatment, biological volume or final polishing.

Slaughtering schedule, daily flow and hourly peaks
Blood, fats, hair, solids and cleaning-chemical inputs
COD, BOD, SS, ammonia, oil and grease, pH and temperature
Applicable discharge or reuse requirement
Footprint, access, utilities and solids-disposal plan
Engineering Decision

Why Separation, A/O And Sedimentation Were Combined

Each stage addresses a different treatment duty. The sequence protects the biological process, reduces dissolved pollution and separates the remaining solids before discharge.

01

Remove Coarse Solids First

Front-end solid-liquid separation removes larger suspended material before it reaches pumps and biological zones, reducing blockage risk and avoidable solids loading.

02

Stage The Biological Duties

The anaerobic zone begins organic breakdown. The oxic zone continues organic oxidation and supports ammonia conversion under aerated conditions.

03

Clarify After Biology

Coagulant addition helps fine particles and colloids form settleable flocs so gravity sedimentation can improve final solids separation.

Equipment Integration

How The Factory-Built Unit Supports The Route

The large rectangular enclosure brings the main treatment functions into one equipment form while keeping project interfaces accessible for transport and site connection.

Main Enclosure

Integrated Carbon-Steel Unit

The project used a large rectangular treatment enclosure prepared as one transportable equipment assembly.

Process Zoning

Functions Arranged Around The Stated Route

Solid-liquid separation, A/O treatment and sedimentation were coordinated as distinct duties within the overall project configuration.

Access And Interfaces

Openings And Service Access Prepared At The Factory

The loading views show access doors, ventilation, external connections and support frames prepared around the enclosure.

Project Services

From Design Through Commissioning

The project scope covered system design, installation, commissioning and after-sales support rather than equipment fabrication alone.

Factory Loading

Integrated Treatment Enclosure Prepared For Transport

The second loading angle shows the enclosure scale, adjacent support frames and transport securing before the equipment left the factory.

Slaughterhouse Wastewater Treatment Project for Pig Farm in Hunan
Loading Detail

Main Enclosure And Project Frames Loaded Together

The equipment was prepared as a large factory-built assembly. Site lifting, foundations, pipe connections, utilities and solids handling still form part of the installation plan for any comparable project.

Full-size rectangular treatment enclosure
External access and ventilation points
Adjacent structural support frames
Low-bed transport and securing arrangement
Main Treatment Stages

Treatment Functions In The Hunan System

The project route addresses coarse solids, biodegradable organic matter, ammonia conversion and final suspended-solids separation without treating the three stages as interchangeable.

Treatment AreaProject ConfigurationEngineering Role
Front-End SeparationPhysical solid-liquid separationRemoves large particles and suspended solids before biological treatment, helping protect downstream equipment and reduce solids loading.
Anaerobic StageAnaerobic biological zoneBegins decomposition of organic matter under oxygen-limited conditions and prepares the wastewater for the aerated stage.
Oxic StageAerobic biological zoneContinues oxidation of organic pollutants and supports nitrification of ammonia under aerated conditions.
Final SedimentationCoagulant-assisted gravity settlingAggregates fine suspended and colloidal particles into flocs that can settle from the treated water.
Solids InterfaceSeparated solids and settled sludgeA repeat project must define collection, dewatering, storage and disposal around the selected treatment route.
Outlet RequirementNational discharge requirements for the projectThe exact applicable standard, limits and sampling point should be confirmed before final equipment sizing.

We configure the route from the slaughter process, real influent data, peak timing, outlet target, site conditions and the required equipment and service scope.

Project Results

Results After Installation And Commissioning

The operating project achieved compliant discharge and high removal of the main stated pollutant groups through the combined treatment route.

Compliant Effluent

The treated wastewater met the national discharge requirements stated for the Hunan project.

Organic Pollutant Control

The combined process achieved high-efficiency removal of organic pollutants.

Ammonia And Solids Reduction

Ammonia nitrogen and suspended solids were reduced through the biological and separation stages.

Stable Project Operation

Design, installation, commissioning and after-sales support were coordinated to maintain stable operation.

Project Status

Installed, Commissioned And Operating

The factory views show the unit before dispatch; the completed project subsequently moved through installation and commissioning into stable operation.

Send Slaughterhouse Water Data
Related Configuration Review

Compare The Project Route With MV-Type And Pretreatment Options

A new slaughterhouse project may use a different equipment form when land, transport, capacity, influent load or expansion requirements change.

Route Used In This Project

Integrated A/O Treatment With Final Sedimentation

The Hunan system was configured around the three treatment duties stated for the project.

Solid-Liquid Separation → A/O Biology → Sedimentation

This route achieved the stated project outcome, but a new system still requires its own hydraulic, pollutant-load and outlet review.

MV-Type Option For A New Project

30-500 m3/day Modular Vertical Plant Family

MV-Type combines AAO, moving bed biofilm reactor (MBBR), high-efficiency sedimentation and high-efficiency filtration in a multi-module vertical format.

AAO + MBBR → Sedimentation → Filtration ▥ ▥ ▥ ▥

The installed Hunan equipment is not identified as MV-Type. For a new slaughterhouse, MV-Type should be evaluated only after solids, blood, oil and grease, peak flow, biodegradability, available footprint and outlet requirements are checked; DAF or other front-end separation may still be required.

Industry Treatment Route

Food And Meat Processing Wastewater

Review high organic load, fats, solids, cleaning chemicals, biological treatment and outlet planning for food and slaughter applications.

Evaluate Meat Processing Routes
MV-Type Equipment

Modular Wastewater Treatment Systems

Compare MV-Type capacity, module grouping, site conditions and the differences between modular vertical and other packaged configurations.

Review MV-Type Systems
Conditional Pretreatment

Dissolved Air Flotation Systems

Evaluate DAF where fats, fine suspended solids and light flocs require stronger front-end separation before biological treatment.

Review DAF Pretreatment
Engineering Support

Project Design And Equipment Configuration

Prepare flow, wastewater indicators, site limits, target standards and supply scope for a slaughterhouse-specific route review.

Prepare Design Inputs
Project Questions

What To Check Before Planning A Similar System

The next design should respond to the slaughter process, production peaks and measured wastewater load instead of copying the 100 m3/day configuration by capacity alone.

Which treatment route was used for the Hunan slaughterhouse project?

The approximately 100 m3/day project used solid-liquid separation, Anaerobic-Oxic (A/O) biological treatment and coagulant-assisted sedimentation.

Why is solid-liquid separation placed before biological treatment?

Slaughterhouse wastewater can carry hair, tissue, coarse solids and other suspended material. Removing larger solids first helps protect pumps and biological zones and reduces avoidable solids loading.

What results were achieved after commissioning?

The treated wastewater met the national discharge requirements stated for the project. The combined route achieved high-efficiency removal of organic pollutants, ammonia nitrogen and suspended solids, and the system operated stably.

Can MV-Type be used for a 100 m3/day slaughterhouse project?

It can be evaluated, but capacity alone is not enough to select it. MV-Type covers 30-500 m3/day and uses AAO, MBBR, high-efficiency sedimentation and filtration. Slaughterhouse solids, blood, fats, peak flow, biodegradability, footprint and outlet requirements must be checked before choosing the equipment form.

When should DAF pretreatment be considered?

Dissolved air flotation should be reviewed when fine suspended solids, oil and grease or light flocs remain difficult to separate with basic screening and settling. Jar tests and wastewater analysis help confirm the dosing and flotation requirement.

What information is needed for a slaughterhouse wastewater RFQ?

Send the animal type and production schedule, average and peak flow, available COD, BOD, SS, ammonia, oil and grease, pH and temperature data, the required outlet, site layout, utilities and expected installation and commissioning scope.

Similar Slaughterhouse Project RFQ

Request A Slaughterhouse Wastewater System Review

Send one set of production, water and site inputs. Our engineering team will review pretreatment, the biological route, equipment form and the interfaces needed for your project.

Animal type, slaughtering schedule and cleaning cycle
Average, peak and daily design flow
COD, BOD, SS, ammonia, oil and grease, pH and temperature
Discharge or reuse target and local requirements
Footprint, access, utilities and required service scope

Motiva RFQ / Water Data Form

Water-quality reports, production information, site layouts and project photographs can be included with the inquiry.

Attach PDF, Excel or image reports when available. Actual configuration depends on wastewater characteristics and project requirements.

Great! We have received your message. Someone in charge will contact you shortly.

We are unable to process your submission. Please try again.

滚动至顶部

Request A Quote

Attach PDF, Excel or image reports when available. Actual configuration depends on wastewater characteristics and project requirements.

Great! We have received your message. Someone in charge will contact you shortly.

We are unable to process your submission. Please try again.