Installed Industrial Wastewater Project / Hunan

60 + 300 m3/day Integrated Industrial Wastewater Treatment Plants In Hunan

Motiva manufactured, installed and commissioned two above-ground integrated wastewater treatment plants for an industrial wastewater project in Hunan, China. The two equipment sets provide stated capacities of 60 and 300 m3/day, for a combined 360 m3/day.

Compare Packaged Plants
Installed Project View Hunan industrial wastewater treatment plant project visual
Two integrated treatment plants installed on site

The project view shows the two equipment bodies, external pipework, pumps and maintenance access used in the installed layout.

2 Equipment Sets

Integrated treatment plants

60 + 300 m3/day

Stated capacities

Hunan, China

Project location

Installed & Commissioned

Documented project stage
Project Overview

What Was Installed For The Hunan Project

The project combines two integrated treatment plants of different capacities in one installed system. The source record confirms manufacturing, site installation and commissioning without publishing the internal process route or numerical water-quality results.

Project At A Glance

LocationHunan Province, China
Wastewater sourceIndustrial wastewater from local industry
Installed capacity60 + 300 m3/day (360 m3/day total)
Equipment quantityTwo integrated wastewater treatment plants
Equipment formAbove-ground integrated wastewater treatment equipment
Treatment approachCustomized integrated route for the site's industrial wastewater
Project scopeManufacturing, installation, commissioning, operation and after-sales service
Project stageInstalled and commissioned
Project Scope

What The Dual-System Installation Shows

The real site photographs establish the equipment quantity, relative scale, above-ground installation form and visible site interfaces. For a comparable industrial project, Motiva confirms:

Wastewater analysis and the required treatment route
Capacity split, flow balance and operating philosophy
Foundations, site access, utilities and hydraulic interfaces
Commissioning scope and performance acceptance criteria
Engineering Context

Engineering Value Of The 60 + 300 m3/day Configuration

The documented project confirms two different equipment capacities. In similar projects, this form can help engineers separate hydraulic duties, match distinct wastewater streams or create a staged operating arrangement after the actual flow balance is verified.

01

Separate Capacity Blocks

Two capacity blocks provide a practical basis for distributing flow or serving different operating duties. The final allocation should follow average and peak flow, wastewater characteristics and the operating schedule.

02

Above-Ground Access

External stairs, platforms and visible connections make routine inspection and equipment access easier to plan than a fully buried installation, subject to the final site layout.

03

Site-Specific Integration

The treatment bodies must connect with pumps, pipework, electrical supply, foundations and upstream or downstream facilities. These interfaces are confirmed during project design.

System Integration

Installed Equipment Built Around Site Interfaces

The project photographs show that a complete integrated installation is more than the treatment body. Hydraulic connections, access arrangements and the transition from factory manufacture to site commissioning are part of the delivered project scope.

Equipment Form

Two Integrated Treatment Bodies

Separate 60 and 300 m3/day above-ground equipment sets form the core of the documented installation.

Hydraulic Interface

External Pumps And Pipework

Visible pumps, valves and pipework connect the treatment equipment with the site's hydraulic system. Duties and materials are confirmed in the project design.

Operation

Maintenance Access

Stairs, platforms and top access support inspection and maintenance around the equipment bodies.

Delivery Scope

Manufacturing Through Commissioning

The source record covers manufacturing, installation, commissioning, operation and after-sales service for the Hunan project.

Installed Equipment Detail

Pumps, Pipework And Access Built Into The Installed Layout

The close project view records the smaller integrated treatment body together with its external hydraulic connections and operating access.

hunan industrial wastewater treatment plant wide view
Visible Project Details

Installed Equipment And External Interfaces

The site image provides practical evidence of how the integrated equipment connects with the surrounding installation.

Above-ground integrated treatment body
External pumps, valves and hydraulic pipework
Stair and platform access for inspection
Installed arrangement beside the larger treatment unit
Installed-System Functions

Installed-System Functions And Engineering Interfaces

This table separates what the project photographs and source record confirm from the engineering functions that must be coordinated in a new industrial wastewater installation.

Project AreaInstalled ConfigurationEngineering Role
Capacity Arrangement60 and 300 m3/day treatment unitsProvides separate capacity blocks that can be allocated according to the verified flow balance and operating plan.
Treatment EquipmentTwo above-ground integrated treatment bodiesProvides a factory-built equipment form; the internal process is selected separately from influent data and outlet requirements.
Hydraulic ConnectionsExternal pumps, valves and pipeworkConnects the equipment to site conveyance and other facilities. Pump duty, pipe material and control points are confirmed by the project P&ID.
Operation And MaintenanceStairs, platforms and top accessSupports inspection, routine operation and planned maintenance around the installed equipment.
Project DeliveryManufacturing, installation, commissioning, operation and after-salesAligns factory production, site work, startup support and post-installation service within one documented project scope.

Project-specific process selection: the source document states that the treatment technologies were customized for the site's industrial wastewater, but it does not name the internal process stages. For a new project, the route is confirmed from representative influent data, flow variation, discharge or reuse targets, site conditions and required supply scope.

New-project interface review: submit the site layout, access limits, foundations, utilities and required manufacturing, installation and commissioning scope with the water data.

360
Project Status

Two Integrated Systems Installed And Commissioned In Hunan

The documented scope covers manufacturing, installation, commissioning, operation and after-sales service for the 60 and 300 m3/day equipment sets.

From This Project To Your Plant

Connect The Hunan Installation To Your Equipment Scope

Use the installed project as physical evidence, then review the industrial treatment route, equipment form and engineering interfaces that fit your own wastewater and site.

Industry Solution

Industrial Wastewater Treatment

Review how wastewater source, pollutant profile, flow variation and outlet targets shape an industrial treatment route.

Explore Industrial Treatment
Integrated Equipment

Package Wastewater Treatment Plants

Compare factory-built equipment forms, capacity options, site connections and project-specific configuration inputs.

Compare Package Plants
Equipment Portfolio

Wastewater Treatment Equipment

Review equipment families that can be combined around the selected industrial wastewater process route.

Review Treatment Equipment
Engineering Support

Project Design And Site Interfaces

Turn water data, site conditions, outlet limits and supply scope into a project-specific process and equipment review.

Prepare Design Inputs
Project Questions

Answers For Buyers Planning A Similar Industrial Project

These answers connect the documented Hunan installation with the decisions required for a new integrated industrial wastewater treatment project.

What is the treatment capacity of the Hunan project?

The project uses two integrated treatment plants with stated capacities of 60 and 300 m3/day, providing a combined installed capacity of 360 m3/day.

What type of equipment was installed?

Two above-ground integrated industrial wastewater treatment plants were installed. The project photographs also show external pumps, valves, pipework, stairs and operating access.

Were installation and commissioning included?

Yes. The source record describes a scope covering manufacturing, installation, commissioning, operation and after-sales service.

Which treatment process was used inside the equipment?

The source states that treatment technologies were customized for the site's industrial wastewater but does not name the internal process stages. A new route should be selected from representative water analysis, flow variation and the required outlet target.

Why might an industrial project use more than one treatment unit?

Multiple units can support separate capacity blocks, different wastewater streams, staged operation or future operating flexibility. The appropriate arrangement depends on the verified hydraulic balance and operating plan.

What data should be submitted for a similar project?

Send the wastewater source, average and peak flow, representative water analysis, discharge or reuse target, site layout, access limits, available utilities and the required manufacturing, installation and commissioning scope.

Industrial Project RFQ

Request An Industrial Wastewater Project Review

Use the shared Motiva RFQ / Water Data Form to provide the wastewater source, flow, water-quality data, outlet target and site interfaces that determine the treatment route and equipment scope.

Wastewater source and average/peak flow
Representative influent analysis and flow variation
Discharge, reuse or downstream treatment target
Site footprint, access, foundations and utilities
Required manufacturing, installation and commissioning scope

Motiva RFQ / Water Data Form

Water-quality reports, site layouts, process notes and project photographs can be included with the inquiry.

Attach PDF, Excel or image reports when available. Actual configuration depends on wastewater characteristics and project requirements.

Great! We have received your message. Someone in charge will contact you shortly.

We are unable to process your submission. Please try again.

滚动至顶部

Request A Quote

Attach PDF, Excel or image reports when available. Actual configuration depends on wastewater characteristics and project requirements.

Great! We have received your message. Someone in charge will contact you shortly.

We are unable to process your submission. Please try again.